BI-TORQ® Valve Automation's "deep base" model is designed so that auxiliary equipment such as modulating positioner boards can be fit into a single enclosure in our smaller 200 and 300 inch pound torque output model. The top indicator is eliminated but this model retains all of the features available in our standard model, including ISO mounting.
Unit of Measure
Features and Options (115 VAC Model)
Torque Output BI-200 ....... 200 inch pounds
BI-300 ....... 300 inch pounds
Cycle Time BI-200 ....... 10 sec at 90º
BI-300 ....... 10 sec at 90º
Duty Cycle 25%
Standard Motor 115 VAC/1 ph/60 hz
Standard Enclosure NEMA 4
Enclosure Material Aluminum
Enclosure Coating Thermal Bonding Polyester Powder
Temperature Rating -40 ºF to +150 ºF (heater required below 0 ºF)
Thermal Overload Protection Standard
Manual Override Standard on NEMA 4 enclosures
Lock Rotor Current BI-200 ..... 0.75 amps
BI-300 ..... 0.75 amps
Switches 15 A, 1/2 hp, 125/250 VAC/125 VDC
Weight 9 pounds
Note For other voltages and combinations, please contact our technical sales staff.